In AC 10, I'd configured the Firefighter workflow per the default settings, and was having an issue with the URL for the log files not being sent in the emails. That has since been addressed by using SE61 to modify the appropriate template.
However, we'd opened a message with SAP, and they'd recommended that we apply note
0001858555 GRC EAM10.0 Completed work flow cannot be reviewed
On applying this note, we are now no longer able to view the Firefighter log, instead seeing an error as follows:
Error analysis
The following syntax error was found in the program
/1BCWDY/TMB6J4Y2MCJ0TBFKHF16==CP :
"Field "GRACA_C_ACTION-AUTH_OBJ" is unknown. It is neither in one of th"
"e specified tables nor defined by a "DATA" statement."
" "
" "
Web Dynpro Component GRAC_UI_SPM_AUDIT_WF
Controller COMPONENTCONTROLLER
We're trying to figure out how to address this issue and SAP hasn't been able to get back to us with a solution.
Have any of you encountered this error?
Thanks,
Santosh
TL;DR: Implemented SAP note on recommendation from SAP, ended up no longer being able to view Firefighter logs.